Audience Response Systems


Wireless
Troubleshooting




All wireless terminals not returning responses to audience polls or diagnostic program



1.

Make sure Wireless Interface is plugged in and turned on, and the red power LED on the interface is glowing.

2.

Check for solid connection of the serial cable between the interface and the computer, using the thumb-screws for secure attachments.

3.

Turn off the interface, wait 5 seconds and turn it back on, then retest.

4.

Check that the COM: port settings in the \windows\ars.ini file matches the port number the interface is connected to.

5.

Replace the serial cable between the interface and the computer.

6.

Replace the Wireless interface with a spare.

7.

If a second serial port is available on the computer, switch the serial cable to that port and change the COM: port settings in the ars.ini file, then reboot the computer and retest the keypad system.

8.
Replace the computer with a spare unit.



BACK TROUBLESHOOTING HOME NEXT




LogoARS Homepage


Thank you for visiting Audience Response Systems Inc.


Call 1-800-INVOLVE ( 468-6583 )
Today to Get the Power



If you encountered errors, or had other difficulty using our site,
please email:
webmaster@audienceresponse.com